Bio-fresh absorption test results
FACTS OF THE CASE
Test of the absorption capacity of Ethanol and Ethylene of the Bio Fresh Masterbatch additive at room temperature. TEST MATERIAL
5 kgs Masterbatch, white cylinders, diameter approx. 3 mm length approx. 3 mm, shrink-wrapped in Polyethylene bag. TEST METHOD Determination of the absorption capacity.
5 - 10 g Masterbatch had been dried during 3 hours at 1050 C in the dry-cupboard and afterwards transferred into a top-opened receptacle in an Exsikkator (volume approx. .4,8 1).
Determination of the Ethylene absorption.
The Exsikkator was rinsed with Ethylene and stored during altogether 30 days.
The Determination of Ethylene absorption had been done gravimetricallyl and also via GC. The gaschromatographical determination was done via Headspace-technology (heating up to 900 C, 30 min.) on a gaschromatopgraph, instrument no.: 319, separation column: B. There were done 4 determinations at atime.
Determination of the Ethanol absorption
An open receptacle with absolute Ethanol was put into the Exsikkator and
stored for 25 days totally. The determination of Ethanol absorption had been done gravimetrically and also via GC. The gaschromatographical determination was done via Headspace-technology (heating up to 900 C, 30 min.) on a gaschromatopgraph, instrument no.: 319, separation column: GS-B. There were done 4 determinations at a time.
TEST RESULTS
GRAVIMETRICAL DETERMINATION
OF ETHANOL - AND ETHYLENE ABSORPTION TABLE # 1 GRAVIMETRICAL DETERMINATION OF ETHANOL AFTER A 25-DAY PERIOD OF STORAGE
|
SAMPLE NUMBER
|
WEIGHT BEFORE TEST
|
WEIGHT AFTER TEST
|
INCREASE IN WEIGHT (g)
|
INCREASE IN WEIGHT (%)
|
|
1
|
7,3870
|
7,6201
|
0,233
|
3,16
|
|
2
|
7,4052
|
7,6441
|
0,2389
|
3,23
|
|
3
|
6,5840
|
6,7959
|
0,2119
|
3,22
|
|
4
|
7,3344
|
7,5679
|
0,2335
|
3,18
|
|
MW
|
|
|
|
3,20
|
|
S
|
|
|
|
0,03
|
TABLE # 2
GRAVIMETRICAL DETERMINATION OF ETHYLENE ABSORPTION AFTER A 30-DAY PERIOD OF STORAGE
|
SAMPLE NUMBER
|
WEIGHT BEFORE TEST
|
WEIGHT AFTER TEST
|
INCREASE IN WEIGHT (g)
|
INCREASE IN WEIGHT (%)
|
|
1
|
5,8927
|
5,9205
|
0,0278
|
0,47
|
|
2
|
5,7042
|
5,732
|
0,0278
|
0,49
|
|
3
|
6,0087
|
6,0530
|
0,0443
|
0,74
|
|
4
|
6,7106
|
6,7566
|
0,0460
|
0,69
|
|
MW
|
|
|
|
0,60
|
|
S
|
|
|
|
0,14
|
GASCHROMATOGRAPHICAL DETERMINATION
OF ETHANOL AND ETHYLENE ABSORPTION TABLE # 3 GASCROMATOGRAPHICAL DETERMINATION OF THANOL-ABSORPTION AFTER A 25-DAY PERIOD OF STORAGE
|
SAMPLE NUMBER
|
WEIGHT BEFORE TEST
|
CONTENT (mp)
|
CONTENT (%)
|
|
1
|
1,0144
|
22,4
|
2,20
|
|
2
|
1,2207
|
28,8
|
2,36
|
|
3
|
1,0335
|
22,3
|
2,16
|
|
4
|
0,9843
|
18,1
|
1,84
|
|
MW
|
|
|
2,14
|
|
S
|
|
|
0,22
|
TABLE # 4
GASCHROMATOGRAPHICAL DETERMINATION OF ETHYLENE ABSORPTION AFTER A 30-DAY PERIOD OF STORAGE
|
SAMPLE NUMBER
|
WEIGHT BEFORE TEST
|
CONTENT (mp)
|
CONTENT (%)
|
|
1
|
1,6040
|
2,1
|
0,60
|
|
2
|
1,0377
|
6,3
|
0,60
|
|
3
|
1,3068
|
8,1
|
0,62
|
|
4
|
1,5003
|
9,2
|
0,61
|
|
MW
|
|
|
0,54
|
|
S
|
|
|
0,14
|
Conclusion
The tested Bio fresh Masterbatch shows an Ethanol absorption
of 2,14 +/- 0,22 Gew % after a 25-day lasting storage period at room temperature in saturated Ethanol atmosphere. The Ethylene absorption amounts to 0.54 +/- 0,14 Gew % after a 30-day
lasting storage period at room temperature in Ethylene atmosphere. The measured values gained during the gravimetrically test
especially of Ethanol are somewhat higher than the gaschromatographical values. The reason for this result is, that also the water absorption is measured while the gravimetrical method.
Grofit Plastics August, 1999.
|